I wrote a script fetching the RAID configuration of the latest VirtualDisk.
On one server I get :
# omreport storage vdisk controller=0 -fmt ssv | awk '-F;' '/^ID/{print}/Virtual\s*Disk\s*[0-9]+;/{line=$0;value=$7}END{print line;print value}'
ID;Status;Name;State;Hot Spare Policy violated;Encrypted;Layout;Size;T10 Protection Information Status;Associated Fluid Cache State ;Device Name;Bus Protocol;Media;Read Policy;Write Policy;Cache Policy;Stripe Element Size;Disk Cache Policy
14;Ok;VirtualDisk16;Ready;Not Applicable;No;RAID-0;7,451.50 GB (8000987201536 bytes);No;Not Applicable;/dev/sdo;SAS;HDD;No Read Ahead;Write Through;Not Applicable;64 KB;Unchanged
RAID-0
#
On another server, I get :
# omreport storage vdisk controller=0 -fmt ssv | awk '-F;' '/^ID/{print}/Virtual\s*Disk\s*[0-9]+;/{line=$0;value=$7}END{print line;print value}'
ID;Status;Name;State;Hot Spare Policy violated;Virtual Disk Bad Blocks;Encrypted;Layout;Size;T10 Protection Information Status;Associated Fluid Cache State ;Device Name;Bus Protocol;Media;Read Policy;Write Policy;Cache Policy;Stripe Element Size;Disk Cache Policy
16;Ok;Virtual Disk 16;Ready;Not Applicable;No;No;RAID-0;3,725.50 GB (4000225165312 bytes);No;Not Applicable;/dev/sdp;SAS;HDD;Read Ahead;Force Write Back;Not Applicable;64 KB;Disabled
No
#
The difference between these two servers is the PERC H730 Mini firmware version :
According to omreport system version
, the first has PERC H730 Mini v25.5.2.0001
and the second PERC H730 Mini v25.5.0.0018
.